omega-qr-code OMEGA微信公众号
咨询热线 400-820-0559

浸没式压力传感器

PXM709GW Series

Submersible Pressure Transducers | PXM709GW Series

Submersible Pressure Transducers

查看下面所有型号

CE
  • Precision Micromachined Silicon Sensor
  • 5-Point NIST Traceable Calibration
  • Lightning/Surge Protection Available on Amplified Models
  • 316L SS Case and Diaphragm
  • Fused Polyurethane Cable
  • mV/V, 0-10 Vdc, or 4-20 mA Output
  • Premium Temperature Performance
  • Broad Compensated Temperature Range
  • 0.20% Standard Accuracy or Optional 0.08% High Accuracy Models for Precise Depth Measurement
  • Available in Gage Pressure: Vented to Atmosphere Through the Cable; Sealed Gage: Not Vented to Atmosphere; or Absolute Pressure: Vacuum Reference
  • Reverse Polarity Protected
  • Protective Nose Cone and Desiccant Available
  • Standard or Custom Cable Lengths
压力传感器 - 查看相关产品

产品描述

The PXM709GW Series submersible depth transducers are designed to make precision level or depth measurements in fresh water or liquids compatible with 316 SS reliably for years in harsh industrial environments. Applications include Level Monitoring and Control, Depth Measurement, Surface Water Monitoring, Tank Level, Well Water Depth, Waste Water Applications,Dewatering Installations and Construction Bypass. Inconel® models are also available for oceanic research and highly corrosive or salt water applications. Consult Sales for availability. The PXM709 series has the proven Omega micromachined silicon technology as its core sensor. The Piezoresistive technology uses precision solid state strain gages molecularly embedded into a highly stable silicon wafer. The silicon is mounted in a sealed chamber and protected from the environmental fluids by a pressure sensitive stainless steel diaphragm. A very small volume of silicone oil transfers the pressure from the diaphragm to the silicon sensor. The cable is molded onto the case using a unique high pressure, high temperature system to assure the best possible quality seal for long life and durability. This technology produces a very rugged, high stability sensor with exceptional accuracy, minimal thermal effects and long term reliability.

COMMON SPECIFICATIONS
Approvals: RoHS compliant
Accuracy (Combined Linearity, Hysteresis and Repeatability): Standard ±0.20% BSL or high accuracy, option “HH”, ±0.08% BSL
Setting Accuracy Zero: ± 0.5% full scale typical, ± 1.0% full scale maximum (± 1.0% full scale typical, ± 2.0% full scale maximum for ranges = 170 mb)
Setting Accuracy Span: ± 0.5% full scale typical, ± 1.0% full scale maximum (± 1.0% full scale typical, ± 2.0% full scale maximum for ranges = 170 mb) calibrated in vertical direction with fitting down
Minimum Resistance Between Transducer Body and Any Wire: 100M Ω @ 50 Vdc (before surge protection)
Pressure Cycles: 1 million minimum
Long Term Stability (1 Year.): ±0.1% full scale typical
Operating Temperature: -18 to 79°C (0 to 175°F) with no solid freeze
Compensated Temperature: -1 to 32°C (30 to 90°F)
Thermal Effects (Over Compensated Range):
Zero Balance:
    Ranges >350 mb: ±0.3% span
    Ranges ≤350 mb: ±0.5% span
Span Setting:
    Ranges >350 mb: ±0.3% span
    Ranges ≤350 mb: ±0.5% span
Bandwidth: DC to 1 kHz typical
Response Time: 500 usec, 0 to 90% step change
CE Compliant: Meets EN 61326-1: 2006 for industrial locations [certified with 91 m (300')]
Lightning Protection Option (if included): Integral lightning surge protection to IEC-61000-4-5 (Level 4)
Shock: 50 g, 11 ms, half-sine horizontal and vertical axis
Vibration: ± 20 g
Overpressure
    Gage and Sealed Gage:
    25 mb: 10 times span
    70 mb: 6 times span
    170 mb to 70 bar: 4 times span
Absolute: 350 mba: 6 times span ranges
    >350 mba: 4 times span
Containment Pressure
    Gage Pressure:
    25 to 350 mb: To 70 bar
    1 to 70 bar: To 200 bar
    Absolute Pressure: 350 mb to 70 bar: To 400 bar
Wetted Parts: 316L stainless steel
Body Material: 316L stainless steel
Pressure Connection: 9/16-18 UNF female
Transducer Weight: 285 g (10 oz) typical depending upon configuration
Cable Construction: Polyurethane jacket with double Kevlar® reinforcing stringers, fused to case, with large vent tube
Cable Pull Strength: 109 kg (240 lb)
Cable Conductors: Four 24 AWG (19/36 stranded tinned copper) with ETFE insulation; meets MIL-W-22759/16 & SAE AS22759/16
Cable Sealing: Fused to case via molded Neoprene boot rated to 610 m (2000') depth
Standard Cable Lengths (meters): 3, 4.6, 6, 7.5, 9, 12, 15, 18, 20, 22.5, 30.5, 45, and 90 for other lengths contact factory for lead times (see page 6)
订购 所有价格均为人民币税前价格,不包括13%增值税和运费!(指定型号)
网上下单立享5%折扣!
产品编号产品描述
数量
产品描述
Gage Pressure with 4-20 ma Output
Quick Ship
PXM709GW-025HGI
咨询  
货期: 
 
 
0.20% accuracy, 0 to 25 mbar, equivalent depth mH20; 0.25, cable length 3 m (10ft)
Quick Ship
PXM709GW-070HGI
咨询  
货期: 
 
 
0.20% accuracy, 0 to 70 mbar, equivalent depth mH20; 0.7, cable length 3 m (10ft)
Quick Ship
PXM709GW-170HGI
咨询  
货期: 
 
 
0.20% accuracy, 0 to 170 mbar, equivalent depth mH20; 1.7, cable length 3 m (10ft)
Quick Ship
PXM709GW-350HGI
咨询  
货期: 
 
 
0.20% accuracy, 0 to 350 mbar, equivalent depth mH20; 3.6, cable length 3 m (10ft)
Quick Ship
PXM709GW-700HGI
咨询  
货期: 
 
 
0.20% accuracy, 0 to 700 mbar, equivalent depth mH20; 7.1, cable length 3 m (10ft)
Quick Ship
PXM709GW-001BGI
咨询  
货期: 
 
 
0.20% accuracy, 0 to 1 bar, equivalent depth mH20; 10, cable length 3 m (10ft)
Quick Ship
PXM709GW-002BGI
咨询  
货期: 
 
 
0.20% accuracy, 0 to 2 bar, equivalent depth mH20; 20, cable length 3 m (10ft)
Quick Ship
PXM709GW-3.5BGI
咨询  
货期: 
 
 
0.20% accuracy, 0 to 3.5 bar, equivalent depth mH20; 35, cable length 3 m (10ft)
Lightning/Surge Protected Model
Quick Ship
PXM709LGW-070HGI
咨询  
货期: 
 
 
0.20% accuracy, 0 to 70 mbar, equivalent depth mH20; 0.7, cable length 3 m (10ft)
Quick Ship
PXM709LGW-170HGI
咨询  
货期: 
 
 
0.20% accuracy, 0 to 170 mbar, equivalent depth mH20; 1.7, cable length 3 m (10ft)
Quick Ship
PXM709LGW-350HGI
咨询  
货期: 
 
 
0.20% accuracy, 0 to 350 mbar, equivalent depth mH20; 3.6, cable length 3 m (10ft)
Quick Ship
PXM709GW-700HGI
咨询  
货期: 
 
 
0.20% accuracy, 0 to 700 mbar, equivalent depth mH20; 7.1, cable length 3 m (10ft)
Quick Ship
PXM709GW-001BGI
咨询  
货期: 
 
 
0.20% accuracy, 0 to 1 bar, equivalent depth mH20; 10, cable length 3 m (10ft)
Quick Ship
PXM709LGW-002BGI
咨询  
货期: 
 
 
0.20% accuracy, 0 to 2 bar, equivalent depth mH20; 20, cable length 3 m (10ft)
Quick Ship
PXM709LGW-3.5BGI
咨询  
货期: 
 
 
0.20% accuracy, 0 to 3.5 bar, equivalent depth mH20; 35, cable length 3 m (10ft)
Ranges Available to 70 bar
Sealed Gage and Absolute Pressure Models also Available

按产品编号购买

产品编号
数量
产品编号
数量


所有金额以RMB显示
注: 1) Comes complete with 5-point NIST traceable calibration certificate.
2) To order with additional cable length, specify total length in meters, additional cost for length over 3 meters. i.e. PXM709GW-001BGI-12M (12 meter cable).
3) To order with optional 0.08% FS accuracy for extra cost, insert code “-HH” after “I”. I.E. PXM709GW-3.5BGI-HH.
4) To order with ½ NPT Conduit fitting for extra cost, specifiy Model PXM709C. i.e.PXM709CGW-170HGI.
5) To order with optional Lightning/Surge protection for extra cost, specify Model PXM709LGW, i.e. PXM709LGW-001BGI.

产品编号生成器

在此处生成您自己的产品编号
选项说明:


(1) Termination 选项:
PXM709 for Waterproof Cable
PXM709C for Waterproof Cable and 1/2 NPT Conduit Fitting

(2) Lighting/Surge Protection (Amplified Models only) 选项:
GW for no protection
LGW for Lightning/Surge Protection

(3) Pressure Ranges 选项:
-025H for 20 mbar
-070H for 70 mbar
-170H for 170 mbar
-350H for 350mbar
-700H for 700 mbar
-001B for 1 bar
-002B for 2 bar
-3.5B for 3.5bar
-007B for 7 bar
-010B for 10 bar
-17.5B for 17.5 bar
-035B for 35 bar
-050B for 50 bar
-070B for 70 bar

(4) Pressure Type 选项:
G for Gage Pressure available in all ranges
SG for Sealed Gage Pressure available from 7 to 70 bar
A for Absolute Pressure available from 350 mbar to 70 bar

(5) Output 选项:
V for mV/V ratiometric output
5V for 0 to 5 Vdc output
10V for 0 to 10 Vdc output
I for 4 to 20 mA output

(6) Accuracy Options (Standard Accuracy 0.2%) 选项:
for
-HH for High (0.08%) Accuracy

(7) Optional Cable Length (standard length 3 m) 选项:
for
-4.5M for 4.5 m cable
-6M for 6 m cable
-7.5M for 7.5 m cable
-9M for 9 m cable
-12M for 12 m cable
-15M for 15 m cable
-18M for 18 m cable
-20M for 19.8 m cable
-22M for 22.5 m cable
-30M for 30 m cable
-45M for 45M cable
-91M for 91 m cable
注: 并非所有组合都有效,请查阅规格表上的有效产品编号。
400-820-0559