omega-qr-code OMEGA微信公众号
咨询热线 400-820-0559

Positive Displacement Flow Meter for Corrosive Liquids

FPD3100

Positive Displacement Flow Meter for Corrosive Liquids | FPD3100

Positive Displacement Flow Meter for Corrosive Liquids

查看下面所有型号

1年保修 CE
  • PPS Body
  • Temperatures up to 80ºC (176ºF)
  • NPT or BSP Threads
涡轮和叶轮流量计 - 查看相关产品

产品描述

The FPD3100 Series positive displacement flowmeters are affordable and accurate. One primary feature is the ability to maintain consistent accuracy despite changing viscosity conditions. The meter’s solid construction and excellent dynamic response are well suited to the measurement of many corrosives as well as other non-abrasive fluids. Since there is no need for straight run piping upstream or downstream of the flowmeter, the FPD3100 flowmeters are simple to use and to install. The meter has good resolution and high accuracy at low flow rates.

Specifications
Accuracy: ±0.5% of reading
Repeatability: ±0.03%
Fitting Type:
    NPT: Female
    BSP: “-BSP” option
Hall-Effect Sensor Power: 4.5 to 24 Vdc (7.5 mA)
Reed Sensor Power: 30 Vdc (500 mA)
Output Options:
    Pulse Output: Standard NPN
    4 to 20 mA Transmitter: “-D-A” option; no output on battery powered “-D” model
Display: 7-digit/12 mm (0.47") upper, 7-digit/7 mm (0.28") lower all “-D” options
    Rate: User defined
    Total: Resettable
    Accumulated-Total: Non-resettable FPD3105
Minimum Viscosity: 1cPs
Maximum Viscosity: 1000 cPs standard
Maximum Pressure: See chart on next page
Strainer Size: See ordering chart on next page
Mounting: Shafts must be in a horizontal plane
Electrical Connections: 2 x 12 mm (0.08 x 0.47"), fittings included “-D-A” option
Cable Length: 1 m (3') stripped ends, non-display models
Mounting: Pipe
Power: 4 to 20 mA, “-D-A” models 18 to 30 Vdc display, “-D” models 3 Vdc lithium battery (included)
Liquid Temperature: -40 to 80°C (-40 to 176°F), -20 to 60°C (-4 to 140°F) for display models
Materials
    Body and Rotors: PPS
    Seals: FFKM, FEP (FPD3105)
    Fasteners: Stainless steel
    Cable Insulation: PVC
    Shaft: Hastelloy C
Enclosure: NEMA 6 (IP67)
订购 所有价格均为人民币税前价格,不包括13%增值税和运费!(指定型号)
网上下单立享5%折扣!
产品编号产品描述
数量
产品描述
Quick Ship
FPD3102
¥8,742.70
货期: 8 周
 
Port Size 1⁄4", Flow Range: <5 cPs, 2 to 100 LPH (0.5 to 26 GPH), >5 cPs 0.5 to 100 LPH (0.13 to 26 GPH), Maximum Pressure psi (Kpa)75 (500)
Quick Ship
FPD3102-D
¥17,847.06
货期: 8 周
 
Port Size 1⁄4", Flow Range: <5 cPs, 2 to 100 LPH (0.5 to 26 GPH), >5 cPs 0.5 to 100 LPH (0.13 to 26 GPH), Maximum Pressure psi (Kpa)75 (500)w/display
Quick Ship
FPD3102-D-A
¥22,491.86
货期: 8 周
 
Port Size 1⁄4", Flow Range: <5 cPs, 2 to 100 LPH (0.5 to 26 GPH), >5 cPs 0.5 to 100 LPH (0.13 to 26 GPH), Maximum Pressure psi (Kpa)75 (500) w/display and analog output
Quick Ship
FPD3103
¥9,524.45
货期: 8 周
 
Port Size 1⁄4", Flow Range: <5 cPs 25 to 500 LPH (6.6 to 132 GPH), >5 cPs 15 to 500 LPH (4 to 132 GPH), Maximum Pressure psi (Kpa) 75 (500)
Quick Ship
FPD3103-D
¥18,626.62
货期: 8 周
 
Port Size 1⁄4", Flow Range: <5 cPs 25 to 500 LPH (6.6 to 132 GPH), >5 cPs 15 to 500 LPH (4 to 132 GPH), Maximum Pressure psi (Kpa) 75 (500) w/display
Quick Ship
FPD3103-D-A
¥23,269.56
货期: 8 周
 
Port Size 1⁄4", Flow Range: <5 cPs 25 to 500 LPH (6.6 to 132 GPH), >5 cPs 15 to 500 LPH (4 to 132 GPH), Maximum Pressure psi (Kpa) 75 (500) w/display and analog output
Quick Ship
FPD3105
¥12,646.38
货期: 8 周
 
Port Size 1", Flow Range: <5 cPs, 3 to 25 LPM (0.8 to 6.6 GPM), >5 cPs2 to 30 LPM (0.5 to 8 GPM), Maximum Pressure psi (Kpa) 150 (1000)
Quick Ship
FPD3105-D
¥21,748.08
货期: 8 周
 
Port Size 1", Flow Range: <5 cPs, 3 to 25 LPM (0.8 to 6.6 GPM), >5 cPs2 to 30 LPM (0.5 to 8 GPM), Maximum Pressure psi (Kpa) 150 (1000) w/display
Quick Ship
FPD3105-D-A
¥26,394.28
货期: 8 周
 
Port Size 1", Flow Range: <5 cPs, 3 to 25 LPM (0.8 to 6.6 GPM), >5 cPs2 to 30 LPM (0.5 to 8 GPM), Maximum Pressure psi (Kpa) 150 (1000) w/display and analog output
所有金额以RMB显示
注: Comes complete with lithium battery (-D) and operator’s manual. For units with a battery powered digital display add “-D” to the model number, for an additional charge. For units with a DC powered digital display and 4 to 20 mA output add “-D-A” to the model number, for an additional charge. For units with BSP connections add “-BSP” to the model number, no additional charge.

产品手册:

下载 Oval Gear Flowmeters for use with Corrosive Chemicals
下载 Digital Displays with Analog Output Options