omega-qr-code OMEGA微信公众号
咨询热线 400-820-0559

FDT100 Series

IN-LINE ULTRASONIC FLOW METER | FDT100 Series

IN-LINE ULTRASONIC FLOW METER

查看下面所有型号

1年保修 CE
  • Economical Ultrasonic Flowmeter for Drinking Water Service
  • Battery Powered
  • Displays Flow Rate and Total
  • Extended Low Flow Range
  • Virtually No Pressure Loss
  • No Moving Parts for Long Life
  • Nist 3 Point Certificate Included
多普勒/渡越时间超声波 - 查看相关产品

产品描述

The FDT100 series has been discontinued. Please see the FDT500 Series as a possible alternative or contact our flow dept. Engineering department.

The FDT100 Series comprises advanced-technology water flowmeters. This series uses transit-time ultrasonic technology in which the signal is transmitted and received alternately between 2 flow sensors and the “time of flight” determines the flow rate. The battery-powered transmitter comes in the user’s choice of an integrally mounted display or a remote-mount version. Applications include both commercial and consumable water measurement. Long-term stability and a wide measurement range make it possible not only to measure water consumption, but also to monitor systems for water leakage. Because the FDT100 Series has no moving parts, system pressure loss is minimal and filtration is not required. Display flow rate or total at the push of a button. Installation is aided by 150-lb ANSI flanges in sizes from 2 to 8".

SPECIFICATIONS
Accuracy: ±2% of reading; ±5% below minimum transition rate
Fluid Temperature: 0 to 50°C (32 to 122°F)
Maximum Pressure: 230 psig
Enclosure: IP67 (integral mount version)
Electronic Housing: Aluminum alloy with plastic cover
Display: 7-segment, 8-digit, single-line LCD
Current Output: 4 to 20 mA/DC current (requires 8 to 24 Vdc supply)
Open Collector Output: 5 to 30 Vdc, 1 mA max
Flange: ANSI 150# or DIN
Meter Body: Cast iron
Power Supply: Internal 3.6V battery (included), 1 to 2 year life

ANSI Size Rate Information
ANSI Flange Size 2 3 4 5 6 8
Overload FLow Rate Qs(GPM) 130 220 350 530 880 1320 1585
Nominal FLow Rate Qp(GPM) 65 110 175 265 440 660 1100
Transitional Flow Rate Qt(GPM) 13 22 35 53 88 132 220
Minimum FLow Rate Qmin(GPM) 2 3.3 5.3 8 13.2 20 33
Pulse Output Constant ki(Gals/pulse) 5 10 10 15 30 30 30

DIN Size Rate Information
DIN Flange Size 32 40 50 65 80 100 125 150 200
Overload FLow Rate Qs(m³/hr) 12 20 30 50 80 120 200 300 360
Nominal FLow Rate Qp(m³/hr) 6 10 15 25 40 60 100 150 250
Transitional Flow Rate Qt(m³/hr) 0.48 0.8 3 5 8 12 20 30 50
Minimum FLow Rate Qmin(m³/hr) 0.12 0.2 0.45 0.75 1.2 1.8 3 4.5 7.5
Pulse Output Constant ki(liters/pulse) 10 25 25 50 50 100 100 100 100

NOTE: HEAVY WEIGHT - OVERWEIGHT SHIPPING CHARGES MAY APPLY FOR THIS PRODUCT. IF ORDERED ON-LINE, INTERNET SALES WILL CONTACT YOU AFTER ORDER PLACEMENT UNLESS YOU OPT TO CHARGE FREIGHT TO YOUR CARRIER ACCOUNT.
订购 所有价格均为人民币税前价格,不包括13%增值税和运费!(指定型号)
网上下单立享5%折扣!
产品编号产品描述
数量
产品描述
150# ANSI Flange Flowmeters
Quick Ship
FDT108
咨询  
货期: 
 
 
15.2 cm (6") Battery-powered ultrasonic flowmeter
Flange 150# ANSI Flowmeters with Remote Electronics
Quick Ship
FDT106-R
咨询  
货期: 
 
 
10.2 cm (4") Battery-powered ultrasonic flowmeter with remote electronics
Accessories
Quick Ship
FDT100-BAT
¥368.11
货期: 2 周
 
Replacement battery for FDT100 Series
所有金额以RMB显示
注: Comes complete with battery, 3-Point Nist Calibration Certificate and operator's manual.

(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)


400-820-0559