The CL510A Series can check and calibrate all your RTD instruments. Take it into the shop, plant or field without worry. It’s easy to operate even in the dark areas of the plant with the backlit display. Stop carrying around a decade box and RTD resistance tables, with the CL510A you can calibrate directly in temperature (°C and °F). Choose between a single RTD type model, CL510A-1 (Pt100, 0.00385), or a CL510A-10 for multiple RTD types.

The CL510A-10 works with a wide variety of RTD curves including Platinm 100 (alpha = 3850, 3902, 3916, 3926) and 1000 (alpha = 3850, 3750) Ω, Copper 10 and 50 Ω, Nickel 100 and 120 Ω. Easily set any value quickly to within 0.1° with the adjustable digital potentiometer "DIAL". Connect directly to RTD inputs of smart transmitters, PLCs, controllers and multichannel recorders and verify their displays.

SPECIFICATIONS (Unless otherwise indicated, all specifications are rated from a nominal 23°C (73°F), 70% RH)
Accuracy: ±(0.015% of Rdg + 0.05 Ω)
Temperature Drift: ±0.05 Ω/°C
Operating Temperature Range: -25 to 60°C (-10 to 140°F)
Relative Humidity Range, 10% ≤RH:
    ≤90%: 0 to 35°C (32 to 95°F), non-condensing
    ≤70%: 35 to 60°C (95 to 140°F), non-condensing
Size: 126 L x 69 W x 45 mm H (4.96 x 2.73 x 1.79")
Weight: 0.24 kg (8.4 oz) (including batteries)
Batteries: 4 "AA" alkaline 1.5V (included)
Battery Life: 50 hr
Low Battery: Low battery indication with nominal 1 hour of operation left
Protection Against Misconnection: Over-voltage protection to 60 Vdc (rated for 30 sec)
Display: High contrast graphic liquid crystal display, LED backlighting for use in low lit areas

Source
Accuracy: From 1 to 10.2 mA
External Excitation Current: ±(0.015% of rdg + 0.05 Ω) Below 1 mA of External
Excitation Current: ±(0.015% of rdg + 0.01 mV/mA excitation current + 0.05 Ω)
Resistance Ranges: 0.00 to 410.00, 410.1 to 4001.0 Ω
Allowable Excitation Current Range, Steady or Pulsed/Intermittent:
    <410 Ω: 10.2 mA max
    410 to 001 Ω: 1 mA max Pulsed Excitation Current
Compatibility: DC to 0.01 second pulse width
订购 所有价格均为人民币税前价格,不包括13%增值税和运费!(指定型号)
网上下单立享5%折扣!

其他客户同时购买: 这个图标可以点击扩大,跳出的清单包括了其他客户在购买此产品时同时购买的其它产品。

产品编号产品描述
数量
产品描述
Quick Ship
  
CL510A-1
¥8,639.86
货期: 7 周
 
RTD simulator, 1 Type (Pt100, 0.00385)
Quick Ship
  
CL510A-10
¥10,910.95
货期: 7 周
 
RTD simulator, 10 Types
Accessories
Quick Ship
Click to expand/minimize a list of what others bought with the020-0209
020-0209
¥943.48
货期: 2 周
 
Rubber boot
Quick Ship
Click to expand/minimize a list of what others bought with theSC-HH500
SC-HH500
咨询  
货期: 
 
 
Soft carrying case
所有金额以RMB显示
注: Comes complete with 4 "AA" alkaline batteries, NIST certificate of calibration (no points), RTD wire kit with 2 red and 2 black leads with retractable shield banana plugs and spade lugs, and operator’s manual.