omega-qr-code OMEGA微信公众号
咨询热线 400-820-0559

适用于频率、电压或电流输出的一体式信号调节器

FLSC-28, FLSC-34, FLSC-35 and FLSC-51B

 | FLSC-28, FLSC-34, FLSC-35 and FLSC-51B

查看下面所有型号

1年保修
  • Up to 0.05% Accuracy
  • Choose from Six Output Types
  • CMOS/TTL Compatible
  • Adjustable Low Level Signal Filter for Noise Rejection
  • Explosion-Resistant Heads
  • For FTB-100 and FTB-200 Turbine Flowmeters
  • Integral Signal Conditioners Available for 4 to 20 mA, 0-5 V, and Factored Pulse Outputs

产品描述

The FLSC-28 Series has been discontinued. Please see the FLSC-C3-LIQ Series as a possible alternative or contact our Flow Engineering Department.

Signal ConditionersCompatible Meters
Model No.
FLSC-34,
FLSC-28, FLSC-35B, FLSC-51
DPF50, DPF60,
DPF300, DPi8
See related links below.
OMEGA™ high accuracy integral signal conditioners are designed for direct mounting onto OMEGA FTB-100 and 200 Series turbine meters. The input circuitry of the signal conditioners has been designed to receive and condition low level turbine meter signals while rejecting unwanted noise and spurious signals. A signal threshold control is provided which allows the user to set the input sensitivity above the ambient noise level, thereby eliminating any false signal on the output. Signal conditioners are available that can provide 4 to 20 mA, 0 to 5V, and scaled frequency pulse outputs that run on unregulated power supplies. Other units which run off 115 Vac provide both an unscaled pulse output and a 0 to 5V or 4 to 20 mA output. A zero and a span potentiometer allow for simple field adjustment of the analog outputs from the signal conditioners.

SPECIFICATIONS
Accuracy: See "To Order" box
Temperature Range: 0 to 70°C (32 to 158°F)
Pulse Output: TTL/CMOS; open collector for FLSC-51B
Input Frequency: 10-1000 Hz, 28 mV P-P; 1000-2500 Hz, 70 mV P-P. Can be used with any OMEGA Turbine Meter
Maximum Input: 120V RMS
Electrical Connections: Screw terminals
Maximum Lead Length: 305 m (1000') of 24 gage copper wire for pulse or mA; 30 m (100') for 0 to 5V output.
Weight: 2.3 kg (5 lb)

Model No. Output Power Accuracy
FLSC-34 4 to 20 mA and unscaled pulse 115 Vac, 50/60 Hz ±0.1% FS
FLSC-28 0 to 5 Vdc 10 to 40 Vdc @ 10 mA ±0.5% FS
FLSC-35B 0 to 5 Vdc and unscaled pulse 115 Vac, 50/60 Hz ±0.1% FS
FLSC-51B scaled squarewave pulse (50 ms duration) 8 to 35 Vdc @ 10 mA ±1% FS
订购 所有价格均为人民币税前价格,不包括13%增值税和运费!(指定型号)
网上下单立享5%折扣!
产品编号产品描述
数量
产品描述
Signal Conditioners
Quick Ship
FLSC-51B
咨询  
货期: 
 
 
Scaled square wave pulse output with 50 ms pulse duration for use with electromechanical totalizers
Popular Compatible Turbine Meters
Quick Ship
FTB-101
¥18,110.35
货期: 7 周
 
1/2" NPT 0.35 to 3.5 GPM
Quick Ship
FTB-102
¥14,050.00
货期: 6 周
 
1/2" NPT 0.75 to 7.5 GPM
Quick Ship
FTB-106
¥20,028.75
货期: 2 周
 
1" NPT 4 to 60 GPM
Quick Ship
FTB-202
¥18,110.35
货期: 9 周
 
37° Flare Fitting, 3/4-16 UNF-3A, 0.75 to 7.5 GPM
所有金额以RMB显示
注: Signal conditioners are installed/scaled at no charge when purchased with turbine meter.

When ordering the Turbine and Signal Conditioner to be scaled and installed as a system, add the cost of the turbine and the signal conditioner together for system cost.

NOTE: The use of explosion-proof heads does not imply that complete assembly is either explosion-proof or intrinsically safe. It is the user’s responsibility to determine the suitability of materials for a given installation.


400-820-0559