Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation
800-819-0559 (Landline) | 400-619-0559 (Cell)
Home >> Temperature Products >> Precision Calibratio... >> Handheld Portable Ca... >> CL510A Series

RTD Simulators

CL510A Series   
3 year warranty CE
 
RTD Simulators
CL510A Series:RTD Simulators
Click for larger image.
   
¥ 10,770.00  CL510A-10
Source One or Multiple RTD Curves
High Accuracy
Easy-to-Read Backlight Display
Calibrate Directly in Temperature (°C or °F)
Compatible with All RTD Process Instruments

View related products - Precision Calibration Equipment and Ice Point References

Click to scroll below to order See Specs PDF Manuals View a printer friendly page

The CL510A Series can check and calibrate all your RTD instruments. Take it into the shop, plant or field without worry. It’s easy to operate even in the dark areas of the plant with the backlit display. Stop carrying around a decade box and RTD resistance tables, with the CL510A you can calibrate directly in temperature (°C and °F). Choose between a single RTD type model, CL510A-1 (Pt100, 0.00385), or a CL510A-10 for multiple RTD types.

The CL510A-10 works with a wide variety of RTD curves including Platinm 100 (alpha = 3850, 3902, 3916, 3926) and 1000 (alpha = 3850, 3750) Ω, Copper 10 and 50 Ω, Nickel 100 and 120 Ω. Easily set any value quickly to within 0.1° with the adjustable digital potentiometer "DIAL". Connect directly to RTD inputs of smart transmitters, PLCs, controllers and multichannel recorders and verify their displays.

SPECIFICATIONS (Unless otherwise indicated, all specifications are rated from a nominal 23°C (73°F), 70% RH)
Accuracy: ±(0.015% of Rdg + 0.05 Ω)
Temperature Drift: ±0.05 Ω/°C
Operating Temperature Range: -25 to 60°C (-10 to 140°F)
Relative Humidity Range, 10% ≤RH:
    ≤90%: 0 to 35°C (32 to 95°F), non-condensing
    ≤70%: 35 to 60°C (95 to 140°F), non-condensing
Size: 126 L x 69 W x 45 mm H (4.96 x 2.73 x 1.79")
Weight: 0.24 kg (8.4 oz) (including batteries)
Batteries: 4 "AA" alkaline 1.5V (included)
Battery Life: 50 hr
Low Battery: Low battery indication with nominal 1 hour of operation left
Protection Against Misconnection: Over-voltage protection to 60 Vdc (rated for 30 sec)
Display: High contrast graphic liquid crystal display, LED backlighting for use in low lit areas

Source
Accuracy: From 1 to 10.2 mA
External Excitation Current: ±(0.015% of rdg + 0.05 Ω) Below 1 mA of External
Excitation Current: ±(0.015% of rdg + 0.01 mV/mA excitation current + 0.05 Ω)
Resistance Ranges: 0.00 to 410.00, 410.1 to 4001.0 Ω
Allowable Excitation Current Range, Steady or Pulsed/Intermittent:
    <410 Ω: 10.2 mA max
    410 to 001 Ω: 1 mA max Pulsed Excitation Current
Compatibility: DC to 0.01 second pulse width
Order on www.omegaengineering.cn and 5% will be discounted when you checkout.
  To Order (Specify Model Number)
All list prices are pre-VAT rate not including tax and shipping
 
 Part Number   Availability   Price(RMB)   Description    Qty.
 Temperature Calibrator
 CL510A-1 2 Weeks   ¥8,075.00    RTD simulator, 1 Type (Pt100, 0.00385)  
 CL510A-10 7 Weeks   ¥10,770.00    RTD simulator, 10 Types  
 Accessories
 020-0209 2 Weeks   ¥930.00    Rubber boot  
 SC-HH500    Consult sales   Soft carrying case  
Price are shown in RMB.

 Note: Comes complete with 4 "AA" alkaline batteries, NIST certificate of calibration (no points), RTD wire kit with 2 red and 2 black leads with retractable shield banana plugs and spade lugs, and operator’s manual.

   
Keywords:RTD Simulators, pt100 calibration, temp sensor calibrator, temperture sensor calibrator, rtd calibrator, proportional directional control valve

   Back to top Back to top